Floor soundproofing in Pakistan: cut footfall and impact noise

The short answer

Floors carry two kinds of noise to the room below: impact noise from footsteps, furniture and equipment, and airborne noise from voices and music. The most effective place to stop impact noise is at the floor itself. Sound Krafted designs floor build-ups that separate your finished floor from the structure, for homes, apartments, studios, gyms and commercial spaces across Pakistan. Working since 2021.

On an RCC slab, a resilient layer under a new screed or a floated board floor isolates footfall at the source. Hard finishes such as tile, stone and hardwood need it most.

Vinyl flooring for quieter rooms

The problem: how noise gets through

Impact noise

Footsteps, heels, dropped objects, chairs and gym equipment. Measured as IIC (ASTM E492/E989) or Ln,w (ISO 717-2, lower is better).

Airborne noise

Voices, TV and music passing down through the floor. Measured as STC; adding mass and a floating layer improves it.

Hard finishes

Tile, stone and hardwood are popular in Pakistan but transmit impact strongly unless laid on a resilient layer.

Flanking at the edges

If a floating floor touches the walls, skirting or pipes, vibration bypasses the isolation. Edge strips keep it separate.

Soundproofing Floors: choose your level

Three levels, from our most complete build-up to a simple upgrade. Each shows the typical lab rating for that assembly.

LEVEL 3 (Best Solution)
Level 3 floor soundproofing build-up, cutaway illustration: typical lab rating STC 67 / IIC 62

A floated floor: two layers of 18 mm plywood bonded with damping compound, laid on a 10 mm resilient underlay. The highest isolation for footfall and airborne noise.

Typical lab rating: STC 67 · IIC 62

  • Floated floor, not fixed through to the structure
  • Effective for both footfall impact and airborne noise
  • Suits hardwood, tile, stone and vinyl; the build-up needs no adhesive
  • Needs the most height: about 46 mm before the finish
Request a site survey →
LEVEL 2 (Standard Solution)
Level 2 floor soundproofing build-up, cutaway illustration: typical lab rating STC 56 / IIC 54

A resilient mat bonded to the existing subfloor or slab, with 18 mm tongue-and-groove board bonded on top. Not fully decoupled, but the next best option where height is limited.

Typical lab rating: STC 56 · IIC 54

  • Resilient mat bonded to the subfloor or slab
  • 18 mm tongue-and-groove board bonded on top
  • Needs less height; suits hardwood and vinyl
  • Two adhesive layers; not a fully isolated floor
Request a site survey →
LEVEL 1 (Basic Solution)
Level 1 floor soundproofing build-up, cutaway illustration: typical lab rating STC 54 / IIC 53

A resilient underlay under the finished floor. It can improve impact performance by around 20 dB, but it is the lowest of the three levels.

Typical lab rating: STC 54 · IIC 53

  • Resilient underlay, about 10 mm, under the finish
  • Improves footfall noise by around 20 dB (supplier figure)
  • Least height and lowest cost
  • For rooms above bedrooms or studios, choose Level 2 or 3
Request a site survey →

Typical laboratory ratings for complete floor/ceiling assemblies (STC to ASTM E90/E413, IIC to ASTM E492/E989). Figures for these levels are as published by a soundproofing supplier and have not been independently verified; treat them as indicative.

Other floor build-ups compared

Build-upTypical ratingNotes
Carpet floor: carpet and pad over resilient underlayabout STC 66 / IIC 68Homes, home cinemas, studios, restaurants and bars
Tile and stone floor: underlay, plywood with damping compound, cement boardabout STC 59 / IIC 57Tile and stone in homes, hotels and commercial space
Floor and ceiling together: floated floor above + isolated ceiling belowSTC 70+ / IIC 62+Highest isolation above and below: studios, cinemas, apartments, hotels

Typical laboratory ratings, shown for comparison. Figures are indicative.

Concrete (RCC) slabs

Build-upIndicative ratingBest for
Bare 150 mm RCC slab with tileSTC 50 to 55 / IIC 25 to 35Footfall clearly heard below
Slab + resilient underlay under the finishIIC +15 to 25Apartments, offices and classrooms
Slab + floating screed (50 to 75 mm) on a resilient layerSTC +5 to 10 / IIC +20 to 30Apartments, hotels, gyms and plant rooms
Slab + floating floor above + isolated ceiling belowSTC 65+ / IIC 60+Studios and cinemas

Indicative ranges for RCC slab buildings common in Pakistan. Estimates from standard references; we confirm on survey.

How we soundproof it

Resilient underlay

A dense rubber or recycled-rubber underlay (typically 5 to 10 mm) under the finished floor softens impact. On its own it can improve impact ratings by around 20 dB.

Floated floor

Two layers of 18 mm plywood or tongue-and-groove board, bonded with damping compound, laid on a resilient underlay without fixing through to the structure. The highest-performing board floor.

Floating screed

A 50 to 75 mm screed poured on a resilient layer over the RCC slab, with isolation strips at all edges. Common for apartments, hotels and plant rooms.

Isolated floor for studios

For studios and cinemas, a heavier floating slab or board floor on rubber or spring isolators, designed for the load.

Edge isolation and sealing

Perimeter strips, skirting fixed to the wall only, and sealed pipe penetrations so the floor stays separate.

Plan for height and finishes

  • Floating floors add roughly 15 to 30 mm (underlay and board) to 75 to 100 mm (screed), so doors, thresholds and stair nosings need adjusting.
  • Hard finishes need the best underlay; carpet gives the highest impact rating on its own.
  • Heavy items such as gym equipment, speakers and plant need a floor designed for the load. We size the resilient layer to the load.
  • For finishes, see our soundproof doors, carpet tiles and wooden flooring.

What the ratings mean

STC: airborne sound

STCWhat you hear next door
25Normal speech is heard and understood
30Loud speech is heard and understood
35Loud speech is heard but hard to follow
40Loud speech is a murmur
45You must strain to hear loud speech
50Loud speech is not heard; loud music is faint (building-code minimum between homes)
55 to 60Most voices, TV and normal music are not heard
60+High isolation: needed for studios, cinemas and bass-heavy music

IIC: impact sound

IICWhat you hear below
Below 45Footsteps, dropped objects and chairs are clearly heard below
50Building-code minimum between homes (45 when field-tested)
55 to 60Good: footfall is soft and occasional
65+Excellent: suits hotels, premium apartments and rooms above studios
  • STC (Sound Transmission Class, ASTM E90 test, E413 rating) rates airborne sound. The European/ISO equivalent is Rw (ISO 717-1), usually within a few points of STC. Higher is better.
  • IIC (Impact Insulation Class, ASTM E492 test, E989 rating) rates footfall through floor/ceilings. The ISO equivalent is Ln,w (ISO 717-2), where lower is better.
  • Lab and field: lab ratings are measured without flanking. Field results (ASTC, FIIC; ASTM E336, E1007) are usually 5 to 10 points lower, so we design with a margin.
  • NRC (noise reduction coefficient, ASTM C423) rates how much sound a surface absorbs, from 0 to 1. It describes echo control, not soundproofing.
  • Building codes: the International Building Code sets STC 50 and IIC 50 (45 when field-tested) as the minimum between homes.

Where we use it

Recording studios and rehearsal rooms
Apartments and hotels
Homes and home cinemas
Offices above occupied floors
Gyms, dance and fitness rooms
Classrooms and auditorium stages
Carpet tiles for sound absorption

Our process

1

Site survey

We visit, note the noise sources and paths, the wall, floor and ceiling construction, and the space available. Start with our free acoustic room checklist.

2

Design and target

We agree a target STC and IIC rating for each element and draw the build-up, including doors, ducts and flanking details.

3

BOQ

You receive a clear bill of quantities with options by level, ready for approval or tender. See our BOQ template and acoustic consultancy.

4

Installation

Our team builds the system with careful sealing and isolation details, and plans noisy work around occupied buildings.

5

Testing and handover

We check the finished room against the brief and hand over the drawings and a summary.

Plan your floor soundproofing

Tell us about the room and the noise. We will visit, set a target rating and prepare a design and BOQ with options. Call or WhatsApp +92 300 8467101, or email info@soundkrafted.com.

Sound Krafted · Main Jinnah Park, Harbanspura, Lahore 54850 · Mon to Sat, 9 AM to 5 PM · info@soundkrafted.com

Request a Site SurveyCall +92 300 8467101WhatsApp

FAQ's

Frequently Asked Questions

Find answers to common questions about our soundproofing and acoustic solutions.

STC rates airborne sound such as voices through the floor. IIC rates impact sound such as footsteps. A floor can score well on STC and still let footfall through, so floors need both ratings.

A good resilient underlay can improve impact noise by around 20 dB and is often enough for homes and offices. For studios, gyms and rooms above bedrooms, a floated floor or floating screed is better.

You can lay a new finish on a resilient underlay over the existing tiles, if height allows. For the best result the new floor must be isolated at the edges as well.

About 15 to 30 mm for an underlay and board floor, and 75 to 100 mm for a floating screed. We check doors, thresholds and stairs at survey.

For footfall, treat the floor first, because that stops impact at the source. For the highest isolation, treat both. See ceiling soundproofing.