Short answer: Soundproofing works through mass, airtight seals and separation. STC (Sound Transmission Class) is the single number that tells you how well a wall, door or window blocks speech. For most offices, the weak point is not the wall itself but the door, the glass, the ceiling void or a duct, so the best result comes from treating every path to a matched rating.

When a client asks us to soundproof a boardroom, a call centre or a plant room, the first question is not “which material?” but “how much isolation do you need, and where does the noise get through?”. This guide explains the materials used in commercial soundproofing, what STC ratings mean in practice, and how to choose a sensible target.

What STC means

STC is a lab rating of how much airborne sound a construction blocks across the speech range. The higher the number, the better the isolation. It is tested under controlled conditions, so a built wall on site usually performs a few points lower than the lab figure, especially if there are gaps, back boxes or a shared ceiling void.

Typical STCWhat you hear through the wallTypical use
25Normal speech understood easilyNot private
35Loud speech heard but not understoodGeneral offices
45Loud speech not heardPrivate offices, meeting rooms
50 to 55Loud music faintly heardBoardrooms, HR and legal suites
60 and aboveMost sounds inaudibleStudios, cinemas, plant room walls

These are widely used guide values, not test results for a particular product.

Typical lab STC ranges for common constructions2030405060Hollow-core doorSTC 18 to 22Solid-core door with sealsSTC 28 to 34Single stud, one board each sideSTC 33 to 38Single stud, boards plus mineral woolSTC 38 to 44115 mm brick, plasteredSTC 43 to 47Two boards each side plus woolSTC 45 to 52230 mm brick, plasteredSTC 48 to 53Acoustic door setSTC 40 to 50Independent lining or double studSTC 55 to 63Typical published lab values. Site results are often several points lower. Your design target comes from the survey.

The three things that stop sound

  • Mass: heavier layers such as extra plasterboard, cement board or masonry block more sound.
  • Airtightness: a small gap can undo a good wall. Sealant at every joint, sealed sockets and door seals matter as much as the wall build-up.
  • Separation: decoupling the two faces of a wall with isolation clips, resilient channel, a staggered or double stud, or an independent lining stops vibration crossing from one side to the other.

Mineral wool in the cavity adds a few points by damping the air space. Thin foam, egg-crate panels and decorative wall panels do not add isolation: they treat echo inside a room. Our guide on soundproofing in Pakistan covers the difference in more detail.

Materials we use, and where

MaterialWhat it doesWhere it is used
Acoustic plasterboard and cement boardAdds dense mass to walls and ceilingsPartitions, linings, isolated ceilings
Mineral wool or glass woolDamps the cavityInside stud walls and ceiling voids
Isolation clips, hangers and channelsDecouple the new layer from the structureWall linings and ceilings
Mass loaded vinylThin, heavy layer for tight spacesInside linings, around ducts
Acoustic sealant and putty padsClose gaps and back boxesEvery joint and service opening
Acoustic door sets and sealsMatch the door to the wallDoors into private rooms
Floating floor underlays and padsCut footfall and machine vibrationFloors above offices and plant

Match the weakest path

A wall is only as good as its weakest element. A high-rated partition with a hollow-core door, single glass or an open ceiling void will perform close to the door or the void. In commercial buildings the common leaks are:

  1. Partitions that stop at the false ceiling, so sound travels over the top.
  2. Doors without perimeter seals and a drop seal.
  3. Single-glazed fronts on meeting rooms.
  4. Shared air-conditioning ducts and return grilles.
  5. Back-to-back sockets and cable openings.

This is why we start every job with a survey and agree an STC target for each path, not just the wall. See meeting room soundproofing and office acoustic solutions for typical office details.

How to choose a target

  • Start from what the room is for: general office, private office, boardroom, studio or plant room.
  • Check the noise on the other side: a corridor, a generator, a road or another meeting room.
  • Agree one target for the wall, door, glazing and ceiling so no element is the weak link.
  • Write it into the BOQ and the tender. Our acoustic tender specification guide shows how.

Common mistakes when choosing soundproofing materials

  • Buying by product name, not by result: a material on its own has no STC. The rating belongs to the full build-up, including the frame, cavity, boards, sealant and how it meets the slab and the floor.
  • Using absorbers to block noise: foam, fabric panels and carpet are useful for echo but light and porous, so they let sound straight through. Our guide to NRC and absorption explains the difference.
  • Stopping the partition at the false ceiling: this is the most common leak we find in offices. The wall should run to the slab above, or the ceiling void needs its own barrier.
  • Forgetting the door and the glass: a well-built wall with an ordinary door or single glass will perform close to the door or the glass. See acoustic glazing vs double glazing.
  • Rigid fixings: screwing a new lining straight to the old wall carries vibration across. Isolation clips and channels are there to break that path.
  • Leaving services until last: sockets, cable trays, ducts and pipes cut holes through the new wall. Plan and seal them at design stage. Our guide on soundproofing HVAC ducts and air vents covers the duct side.

What a site survey checks

Before we recommend a build-up, we visit the building and look at where the sound actually travels. A typical survey covers:

  • The noise source and its character: speech, music, traffic, plant or a generator. Low-pitched noise needs more mass and separation than speech.
  • The existing construction: block, brick, gypsum partition, glass, and what sits above the false ceiling.
  • Every opening: doors, glazing, AC grilles, return air paths, cable openings and back-to-back sockets.
  • Structure and load: whether the floor can take heavier linings or a floating floor.
  • Space and finishes: how much depth you can give up on each wall, and what the room must look like when finished.
  • Working hours and access, so installation can be planned around the people who use the building.

Step by step: from target to installation

  1. Agree the use of each room and how private or quiet it must be.
  2. Set a target for each separating element, such as the wall, door, glazing and ceiling, using typical STC ranges as a guide.
  3. Choose the build-up that reaches the target in the space available, with a margin for site conditions.
  4. Detail the junctions: head of wall, floor junction, door frame, glazing frame and service openings.
  5. Write the BOQ so each layer, seal and fixing is listed and can be checked on site.
  6. Install and inspect before boards are closed, because most leaks are hidden once the wall is finished.
  7. Check the result with a listening test or measurements between rooms.

Typical applications by building type in Pakistan

  • Corporate offices and banks: boardrooms, HR rooms and manager cabins need speech privacy. Walls to the slab, sealed acoustic doors and laminated glazing are the usual combination, often alongside an open-plan noise plan for the main floor.
  • Hospitals and clinics: consultation rooms need privacy, and wards need protection from plant rooms and generators. See generator noise control.
  • Universities and schools: classrooms beside corridors, music rooms and lecture halls each need their own target. Materials must be robust and easy to maintain.
  • Broadcasters and media cells: studios need the highest isolation, often a room within a room. See also TV studio acoustics.
  • Hotels and guest houses: room-to-room walls, corridor doors and rooms above function halls or kitchens.
  • Industrial sites: control rooms and offices beside production halls, compressors and chillers. See industrial noise control.

Durability and maintenance

In Pakistan’s heat and humidity, materials should stay stable over time. Mineral wool should be kept dry inside the cavity, sealants should stay flexible, and door seals need checking as part of routine maintenance, because a worn drop seal is one of the first things to let sound through. When we hand over a project we explain which parts need checking and how often.

Frequently asked questions

What is a good STC rating for an office?

For private offices and meeting rooms, a target of about STC 45 is common, and boardrooms or HR rooms often aim higher. The right figure depends on the noise next door and how private the room must be.

Does acoustic foam raise the STC of a wall?

No. Foam and decorative panels absorb echo inside the room. They are too light and porous to block sound passing through a wall.

Why does my new partition still leak sound?

Usually because sound goes around it: over the top through the ceiling void, under the door, through glass or a shared duct. Each path needs treating to the same level.

Can you test the result on site?

Yes. We can measure before and after so you can see the change in noise between rooms.

Which matters more, the material or how it is installed?

Both, but installation decides the result. Gaps, rigid fixings and unsealed openings can undo a good material, so we inspect each layer before it is closed.

Plan soundproofing for your building

Call or WhatsApp +92 300 8467101 for a free phone consultation, or request a site survey or BOQ review.

Request a Site SurveyCall +92 300 8467101WhatsApp

About Sound Krafted: Working since 2021, our team has delivered 50 projects for 49 organisations, including government departments, universities, broadcasters and corporate organisations. We are based in Lahore and are a project of Media K Solutions (Pvt) Ltd. About us

{“@context”: “https://schema.org”, “@type”: “FAQPage”, “@id”: “https://soundkrafted.com/commercial-soundproofing-materials-stc-ratings/#faq”, “mainEntity”: [{“@type”: “Question”, “name”: “What is a good STC rating for an office?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “For private offices and meeting rooms, a target of about STC 45 is common, and boardrooms or HR rooms often aim higher. The right figure depends on the noise next door and how private the room must be.”}}, {“@type”: “Question”, “name”: “Does acoustic foam raise the STC of a wall?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “No. Foam and decorative panels absorb echo inside the room. They are too light and porous to block sound passing through a wall.”}}, {“@type”: “Question”, “name”: “Why does my new partition still leak sound?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Usually because sound goes around it: over the top through the ceiling void, under the door, through glass or a shared duct. Each path needs treating to the same level.”}}, {“@type”: “Question”, “name”: “Can you test the result on site?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Yes. We can measure before and after so you can see the change in noise between rooms.”}}, {“@type”: “Question”, “name”: “Which matters more, the material or how it is installed?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Both, but installation decides the result. Gaps, rigid fixings and unsealed openings can undo a good material, so we inspect each layer before it is closed.”}}]}